New Handheld ECG/NIBP/SPO2/PR Patient Monitor PM-60D
Introduction:
■ Routine Check Mode and
Continuous Monitoring Mode
■ Data Graph and Trend Table
Review
■ Rich Analysis Report
■ Perfect Mount Solution
■ Convenient operation by touch screen
■ Large SD card memory for more than
2000 patient cases storage
■ Sync with PC based Sofrware (WinXP and WinVista)
Performance Specifications:
■ Display:3.5" Color TFT
■ Resolution:320x240
■ Display Mode:Standard face, Waveform face, SPO2 view,
ECG view, BigNum view
■ Indicator:Power indicator light, Alarm sound, Pluse tone
■ Interface:One dual-purpose socket for connecting sensors
and communication cables
■ Power Supply:DC 5V, <500MA
■ Battery:Builtin Li-Polymer, 2 hours for charging, 3 hours
■ for continous working.10 hours for standby mode
■ Trend Graph:Resolution from 1s, 5s, 10s. Maximum time
96 hours.
■ Trend Table:Resolution from 1s, 5s, 10s. Review up to 1000
items.
■ Alarm:Ajustable High and Low limits. Three level au
dible and vistual alarm
■ User Configuration:All the color of parameters and waves
can be set according to user's willing
Technical specifications:
■ Safety
■ Meet the requirment of IEC60601 series
■ Type of Protection:Class II with internal electirc power
supply
■ Degree of Protection:BF
■ Dimention and Weight
■ Dimention:92(W)x82(H)x22(D)mm
■ Weight:136g(with battery)
■ Operation Environment:
■ Temperature:0℃~ +40℃
■ Humidity:15% ~ 95%
■ Storage Environment:
■ Temperature:-20℃~ +60℃
■ Humidity:10% ~ 95%
■ Patient Range
■ Neonate ,Pediatric and Adult
SPO2:
■ Measurement Range:0 ~ 100%
■ Resolution:1%
■ Accuracy:±2%(70%~100%, Adult/Pediatric, non-motion)
±3%(70%~100%, Neonate, non-motion)
0% ~ 69% unspecified
■ Alarm Range:0% ~ 100%
■ Refreshing Rate:1s
Pulse Rate:
■ Measurement Range:25 ~ 250 bpm
■ Resolution:1bpm
■ Accuracy:± bpm (non-motion)
■ Alarm Range:25 ~ 250 bmp
■ Refreshing Rate:1s
ECG:
■ Lead mode:3-lead or 5-lead
■ Lead selection: I, II, III, AVR, AVL, AVF, V
■ HR range:15 ~ 300 bpm
■ ECG Waveform:2 channals
■ Accuracy:±2bpm or ±2%, which is greater
■ S-T segment detection, range: -2.0mv ~ +2.0mv
■ Arrhythmia analysis: 13 kinds of arrhythmia
■ Alarm Range:15 ~ 300 bpm
NIBP:
■ Method:Oscillometry
■ Mode:Manual/Auto/Contiuous
■ Measurement Range:25 ~ 260mmHg
■ Atuo Measure Interval: 5, 10, 15, 30, 45, 60, 90
minutes
■ Resolution:1mmHg
■ Overpressure Protection: 300mmHg
■ Alarm range:25 ~260mmHg
Attention please, item could only be shipped out via EMS.
For orders from any other countries where there's no EMS
service or orders shipped by other Express company(like
UPS,DHL, FEDEX,)please email us when you placed your order.
Thanks for your reading and cooperation.
Tell us what you think about this item, share your opinion with other people. Please make sure that your review focus on this item. All the reviews are moderated and will be reviewed within two business days. Inappropriate reviews will not be posted.
Have any question or inquire for this item? Please contact Customer Service. (Our customer representative will get back shortly.)